Panacea Medical Technologies Siddharth-II Iconic
SIDDHARTH-II is an advanced 6 MV SBRT Enabled linear accelerator developed and manufactured by Panacea Medical Technologies Pvt. Ltd., India, for external beam radiation therapy in cancer treatment. The system delivers 6 MV photon beams in both Flattening Filter (FF) and Flattening Filter Free (FFF) modes. Built on an innovative ring-gantry platform, it features patented in-gantry kV Cone Beam Computed Tomography (CBCT) and stereo imaging technology for image-guided treatment. Its streamlined four-step workflow, from patient setup to treatment delivery, helps improve treatment efficiency and reduce overall workflow time. The system supports advanced radiotherapy modalities, including 3D Conformal Radiation Therapy (3D-CRT), Intensity-Modulated Radiation Therapy (IMRT) with Image-Guided Radiation Therapy (IGRT), Volumetric Modulated Arc Therapy (VMAT), Stereotactic Body Radiation Therapy (SBRT), and Stereotactic Radiosurgery (SRS).
Usage
In hospitals, cancer centres, radiotherapy departments, and oncology institutions for external beam radiation therapy in the treatment of cancer. Intended for use by trained radiation oncologists, medical physicists, and radiotherapy technologists.
Features & Specifications
Technical Specifications
Photon Energy
6 MV
Gantry
Ring Gantry
Couch
6D Robotic Couch
OBI
Available
Treatment Modalities
3D CRT, IMRT, VMAT, SBRT & SRS
Treatment Workflow
4 Step Intuitive Workflow
OEM
Panacea Medical Technologies Pvt. Ltd
Manufacturing Country
India
Certifications
FDA, CE, CDSCO and AERB Type Approvals
NME1009
Panacea Medical Technologies
Siddharth-II - Iconic
Photon Energy 6 MV
Gantry Ring Gantry
Couch 6D Robotic Couch
EMI Calculator
Loan Amount Starts from (₹1 Lakh)
Minimum loan amount is ₹ 1,00,000
Rate of Interest (6% - 24%)
slider-btn
Duration (In Years)
1 2 3 4 5
Rate of interest @ 6% for slider-btn
The Rate of Interest is calculated as follows
[P x R x (1+R) ^ N]/[(1+R) ^ (N-1)]
Where, P - Principle Amount
R - Monthly Interest
N - Loan Tenure in months
Panacea Medical Technologies Siddharth-II Iconic
Photon Energy 6 MV
Gantry Ring Gantry
Couch 6D Robotic Couch